Square D - 20 Amp, 240 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 14-8 AWG


Item #: 54423744
Brand: Square D
Model #: QOB220H
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 2
Terminal Connection Type Pressure Plate
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 14-8
Standards Met CSA; RoHS Compliant; UL Listed

$312.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 40 Amp, 440 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 18mm Wide


Item #: 56787138
Brand: Schneider Electric
Model #: M9F12140
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 40
Number of Poles 1
Breaking Capacity 10 kA @ 230-240 VAC; 3 kA @ 400-415 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 18-2
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 18
Overall Width (Decimal Inch) 0.7100
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$146.47

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, 240 VAC, 3 Pole, Bolt On Miniature Circuit Breaker - 4-2/0 AWG


Item #: 69660488
Brand: Square D
Model #: QOB390
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 90
Number of Poles 3
Terminal Connection Type Box Lugs
Mounting Type Bolt-on
Voltage 240 VAC
Wire Size (AWG) 4-2/0
Standards Met CSA; RoHS Compliant; UL Listed

$494.28

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56762552
Brand: Square D
Model #: PGL36080U31A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$22,769.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56739683
Brand: Square D
Model #: HDL36015AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 15
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,146.29

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 277 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41394271
Brand: Square D
Model #: BGA140301
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 30
Number of Poles 1
Breaking Capacity 65 kA @ 240 V; 35 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$492.09

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 350 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 8.05 Inch Deep x 12.86 Inch High x 8.27 Inch Wide


Item #: 56760861
Brand: Square D
Model #: MJL36350LW
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 350
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0 (Aluminum); 3/0 (Copper)
Overall Depth (Decimal Inch) 8.0500
Overall Height (Decimal Inch) 12.8600
Overall Width (Decimal Inch) 8.2700
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$14,743.53

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 6 Amp, 2 Pole, Backplate, Clip, DIN Rail Mount Circuit Protector - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 70mm Deep x 74mm High x 30mm Wide


Item #: 56804362
Brand: Schneider Electric
Model #: GB2DB12
Exact Tooling IR#: 04

Features and Benefits

Circuit protectors are designed for protecting relays, motors, heaters, transformers, solenoids and semiconductors from short circuiting. They protect by monitoring the flow of electricity and detecting any imbalances in the electrical device.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Circuit Protector
Amperage 6
Number of Poles 2
Breaking Capacity 1 kA @ 48 VDC; 1.5 kA @ 230/240 VAC; 1.5 kA @ 24 VDC; 1.5 kA @ 400/415 VAC; 3 kA @ 110 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Backplate; Clip; DIN Rail Mount
Durability 8000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 70
Overall Height (mm) 74
Overall Width (mm) 30
Reset Actuator Type Toggle Switch

$144.13

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 Amp, 277 Volt, 1 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46117776
Brand: Schneider Electric
Model #: M9F21116
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 16
Number of Poles 1
Breaking Capacity 10 kA @ 277 VAC; 14 kA @ 240 VAC; 14 kA @ 120 VAC; 10 kA @ 65 VDC; 3 kA @ 415 VAC; 10 kA @ 240 VAC; 20 kA @ 60 VDC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 0.7100
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$102.83

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1200 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56767742
Brand: Square D
Model #: PGL36120U33A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 1200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$31,267.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 25 kA at 347 VAC, 65 kA at 277 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41397563
Brand: Square D
Model #: BJL16110
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 110
Number of Poles 1
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 347 VAC; 65 kA @ 277 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$914.21

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 1 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 56786767
Brand: Schneider Electric
Model #: M9F17201
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 1
Number of Poles 3
Breaking Capacity 20 kA @ 440 VAC; 25 kA @ 400-415 VAC; 50 kA @ 230-240 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$463.02

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 16 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 54mm Wide


Item #: 69660140
Brand: Schneider Electric
Model #: M9F11316
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 16
Number of Poles 3
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 54
Overall Width (Decimal Inch) 2.1300
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$391.11

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 30 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56739576
Brand: Square D
Model #: HDL36030SA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 30
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,797.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Value Collection - Circuit Breakers Circuit Breaker Type: Type II Circuit Breaker Amperage: 15


Item #: 66432543
Brand: Value Collection
Exact Tooling IR#: 04

Product Specifications

Circuit Breakers; Circuit Breaker Type: Type II Circuit Breaker ; Amperage: 15 ; Terminal Connection Type: Blade ; Mounting Type: Plug-in ; Voltage: 6-12 VDC
Circuit Breaker Type Type II Circuit Breaker
Amperage 15
Terminal Connection Type Blade
Mounting Type Plug-in
Voltage 6-12 VDC

$94.94

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56767825
Brand: Square D
Model #: PJL36040CU31A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$37,209.65

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 5 Amp, 480Y/277 V, 2 Pole, DIN Rail Mount Miniature Circuit Breaker - Thermal Magnetic Trip


Item #: 69669018
Brand: Schneider Electric
Model #: MG17434
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 5
Number of Poles 2
Tripping Mechanism Thermal-Magnetic
Mounting Type DIN Rail Mount
Voltage 480Y/277 V

$284.23

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 40 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399692
Brand: Square D
Model #: BDA24040Y1
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 40
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$818.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 65 kA at 600 VAC Breaking Capacity, 14.49 Inch Deep x 16.24 Inch High x 16.54 Inch Wide


Item #: 56761315
Brand: Square D
Model #: RKF36080CU31A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 65 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Terminal Nut
Mounting Type Unit Mount
Voltage 600 VAC
Overall Depth (Decimal Inch) 14.4900
Overall Height (Decimal Inch) 16.2400
Overall Width (Decimal Inch) 16.5400
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$47,677.10

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 63 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 56787252
Brand: Schneider Electric
Model #: M9F11263
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 63
Number of Poles 2
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-35
Wire Size (AWG) 18-2
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$334.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It