We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Contactors & Starters (ET04) - (4029 Products)


Lighting & Electrical > Contactors & Starters (ET04)

Square D - 1 Pole, NEMA Size 2, 45 Amp, 600 VAC and 600 VDC, Thermal NEMA Overload Relay - Trip Class 10 and 30, For Use with Size 2 Starters


Item #: 69682565
Brand: Square D
Model #: 9065TO1
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 2
For Use With Size 2 Starters
Voltage 600 VAC; 600 VDC
Maximum Overload (A) 45
Sensing Method Thermal
Trip Class 10; 30
Number of Poles 1
Overall Height (Decimal Inch) 3-1/4
Overall Height (mm) 82-1/2
Overall Depth (mm) 120.70
Overall Depth (Decimal Inch) 4-3/4
Overall Width (Decimal Inch) 1.3800
Overall Width (mm) 35
Additional Information Separate Mounting Melting Alloy

$139.89

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Poles, 30 Amp, NEMA, Enclosed Toggle Manual Motor Starter - 1 hp at 90 VDC, 10 hp at 460 VAC, 10 hp at 575 VAC, 1-1/2 hp at 230 VDC, 2 hp at 115 VAC, 2 hp at 115 VDC & 7-1/2 hp at 230 VAC


Item #: 49833759
Brand: Square D
Model #: 2510KG2S2
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 30
Operator Type Toggle
Enclosure Type Enclosed
Horsepower (HP) 1 @ 90 VDC; 10 @ 460 VAC; 10 @ 575 VAC; 1-1/2 @ 230 VDC; 2 @ 115 VAC; 2 @ 115 VDC; 7-1/2 @ 230 VAC
Number of Poles 3

$233.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2 Poles, 16 Amp, NEMA, Enclosed Toggle Manual Motor Starter - 1 hp at 115 VAC, 1 hp at 230 VAC, 1 hp at 277 VAC, 3/4 hp at 115 VDC & 3/4 hp at 230 VDC, CE, CSA, NEMA 3R/7/9 & UL Listed


Item #: 56821945
Brand: Square D
Model #: 2510FR2H
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 16
Operator Type Toggle
Enclosure Type Enclosed
Horsepower (HP) 1 @ 115 VAC; 1 @ 230 VAC; 1 @ 277 VAC; 3/4 @ 115 VDC; 3/4 @ 230 VDC
Number of Poles 2
Standards Met CE; CSA; NEMA 3R/7/9; UL Listed

$465.22

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 1 Pole, 0.4 to 16 Amp, NEMA, Open Toggle Manual Motor Starter - 43.2mm Wide x 40.1mm Deep x 96.8mm High, 1 hp at 120/240 V, 1 hp at 277 V, 1/4 hp at 120/240 V & 1/4 hp at 32 V, CSA Certified & UL Listed


Item #: 01259662
Brand: Eaton Cutler-Hammer
Model #: MST01
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Amperage refers to the maximum electrical current the product is intended to accommodate.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type NEMA
Amperage 0.40-16
Operator Type Toggle
Enclosure Type Open
Horsepower (HP) 1 @ 120/240 V; 1 @ 277 V; 1/4 @ 120/240 V; 1/4 @ 32 V
Number of Poles 1
Overall Height (mm) 96.80
Overall Height (Decimal Inch) 3.8100
Overall Width (mm) 43.20
Overall Width (Decimal Inch) 1.7000
Overall Depth (mm) 40.10
Overall Depth (Decimal Inch) 1.5800
Standards Met CSA Certified; UL Listed

$229.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 3 Pole, NEMA Size 0, 00, 32 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 10 and 20, For Use with CE/CN Non-Reversing and Reversing Contactors


Item #: 02300788
Brand: Eaton Cutler-Hammer
Model #: C306DG3B
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 0; 00
For Use With CE/CN Non-Reversing & Reversing Contactors
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Trip Class 10; 20
Number of Poles 3
Standards Met CSA Certified; NEMA Compliant; UL 508 Single Phasing Requirements; UL Listed

$453.70

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 7 to 10 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D09 and LC1D38


Item #: 69648434
Brand: Schneider Electric
Model #: LR3D14
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D09; LC1D38
Voltage 690 VAC
Maximum Overload (A) 10
Sensing Method Thermal
Minimum Overload (A) 7
Trip Class 10A
Overall Width (mm) 70
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 508

$88.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 to 13 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D40A and LC1D65A


Item #: 54525449
Brand: Schneider Electric
Model #: LRD313
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D40A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 13
Sensing Method Thermal
Minimum Overload (A) 9
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$141.80

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 600 Volt, Thermal NEMA Overload Relay


Item #: 54529458
Brand: Square D
Model #: 9065SEO7S1
Exact Tooling IR#: 04

Product Specifications

600 Volt, Thermal NEMA Overload Relay -
Starter Type NEMA
Voltage 600 V
Sensing Method Thermal

$130.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 Pole, 16 Amp, NEMA, Enclosed Toggle Manual Motor Starter - 1 hp at 115 VAC, 1 hp at 230 VAC, 1 hp at 277 VAC, CE, CSA, NEMA 4 & UL Listed


Item #: 56819352
Brand: Square D
Model #: 2510FW1H
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Product Specifications
Starter Type NEMA
Amperage 16
Operator Type Toggle
Enclosure Type Enclosed
Horsepower (HP) 1 @ 115 VAC; 1 @ 230 VAC; 1 @ 277 VAC
Number of Poles 1
Standards Met CE; CSA; NEMA 4; UL Listed

$539.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 3 Pole, 600 VAC, 18 Continuous Amp, 5 hp, Enclosed NEMA Combination Starter - NEMA 12, RoHS Compliant, 30 Amp Short Circuit Protection


Item #: 69649911
Brand: Square D
Model #: 8538SBA23V02S
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Three-phase refers to three individual lines (coils) that connect to and run voltage through the motor. Each line alternates in a sequence as they reach their voltage peak. They provide a more stable flow of voltage and more horsepower to the equipment.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 18
Starter Type NEMA
Enclosure Type Enclosed
Compatible Motor Phase Three Phase
Action NonReversible
Voltage 600 VAC
Number of Poles 3
Horsepower (HP) 5
Short Circuit Protection (A) 30
Standards Met NEMA 12; RoHS Compliant

$1,728.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Cooper Wiring Devices - 2 Poles, 40 Amp, DPST, NEMA, Open Toggle Manual Motor Starter - 56.64mm Wide x 42.16mm Deep x 95.25mm High, 15 hp, CSA C22.2 No. 14, NEMA 1 & UL 508


Item #: 78006707
Brand: Cooper Wiring Devices
Model #: AHMC240C
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type NEMA
Amperage 40
Operator Type Toggle
Enclosure Type Open
Horsepower (HP) 15
Number of Poles 2
Maximum Overload (A) 40
Contact Form DPST
Overall Height (mm) 95-1/4
Overall Height (Decimal Inch) 3-3/4
Overall Width (mm) 56.64
Overall Width (Decimal Inch) 2.2300
Overall Depth (mm) 42.16
Overall Depth (Decimal Inch) 1.6600
Standards Met CSA C22.2 No. 14; NEMA 1; UL 508

$172.35

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 00-1, 5.5 to 8 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 and LC1D38


Item #: 69527315
Brand: Schneider Electric
Model #: LRD12L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 00-1
For Use With LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 8
Sensing Method Thermal
Minimum Overload (A) 5.50
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$82.68

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 5.5 to 8 Amp, 250 VDC, 690 Volt and 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1K, LC7K, LP1K and LP4K


Item #: 64681992
Brand: Schneider Electric
Model #: LR2K0314
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1K; LC7K; LP1K; LP4K
Voltage 250 VDC; 690 V; 690 VAC
Maximum Overload (A) 8
Sensing Method Thermal
Minimum Overload (A) 5.50
Trip Class 10A
Overall Height (mm) 58
Overall Width (mm) 65
Standards Met BS 4941; IEC 60947; NF C 63-650; VDE 0660

$88.26

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 5, 600 VAC, Thermal NEMA Overload Relay - For Use with Motor Logic


Item #: 56825128
Brand: Square D
Model #: 9065ST520
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 5
For Use With Motor Logic
Voltage 600 VAC
Sensing Method Thermal

$337.11

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 250 VAC, IEC Overload Relay


Item #: 56828569
Brand: Schneider Electric
Model #: LT3SM00ED
Exact Tooling IR#: 04

Product Specifications

250 VAC, IEC Overload Relay -
Starter Type IEC
Voltage 250 VAC
Overall Height (mm) 100
Overall Width (mm) 100
Standards Met IEC 60034-11; VDE 0660
Additional Information Dectects Ground Fault

$510.34

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 00, 600 VAC, Thermal NEMA Overload Relay - For Use with Motor Logic


Item #: 57657827
Brand: Square D
Model #: 9065SFC20
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 00
For Use With Motor Logic
Voltage 600 VAC
Sensing Method Thermal

$242.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 1, 23 to 32 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D25, LC1D32 and LC1D38


Item #: 49755630
Brand: Schneider Electric
Model #: LR3D32L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 1
For Use With LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$95.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with A200 3-Phase Starter Size 3, A200 3-Phase Starter Size 4


Item #: 02355030
Brand: Eaton Cutler-Hammer
Model #: FH79
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With A200 3-Phase Starter Size 3; A200 3-Phase Starter Size 4

$91.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 18 Amp, 120 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 3 Phase Hp: 125 at 460 VAC, 125 at 575 VAC, 50 at 208 VAC, 60 at 230 VAC


Item #: 69527638
Brand: Schneider Electric
Model #: LE1D183A62OG70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 18
Coil Voltage 120 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 125 @ 460 VAC; 125 @ 575 VAC; 50 @ 208 VAC; 60 @ 230 VAC
Enclosure Type Enclosed
Number of Poles 3
Standards Met CSA; IEC; NEMA 1; UL

$259.07

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Handle Kit - For Use with TeSys U


Item #: 56804529
Brand: Schneider Electric
Model #: LU9APN21
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Handle Kit
For Use With TeSys U

$211.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It