We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Contactors & Starters (ET04) - (4029 Products)


Lighting & Electrical > Contactors & Starters (ET04)

Springer - 0.65 to 1.1 Amp, IEC Overload Relay - Trip Class 10, For Use with 9-32A JC Contactors


Item #: 54096128
Brand: Springer
Model #: JL1-F
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With 9-32A JC Contactors
Maximum Overload (A) 1.10
Minimum Overload (A) 0.65
Trip Class 10
Overall Height (Decimal Inch) 3.3800
Overall Height (mm) 85.80
Overall Depth (mm) 107.70
Overall Depth (Decimal Inch) 4.2400
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45

$114.67

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 12 Amp, 24 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.5 at 120 VAC, 2 at 240 VAC, 3 Phase Hp: 10 at 575 VAC, 3 at 208 VAC, 3 at 230 VAC, 7.5 at 460 VAC


Item #: 49787047
Brand: Schneider Electric
Model #: LE1D123A62OB70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 12
Coil Voltage 24 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 575 VAC; 3 @ 208 VAC; 3 @ 230 VAC; 7.5 @ 460 VAC
Horsepower at 1 Phase 0.5 @ 120 VAC; 2 @ 240 VAC
Enclosure Type Enclosed
Number of Poles 3
Standards Met CSA; IEC; NEMA 1; UL

$257.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with A200/B100 Starter Size 2


Item #: 02354983
Brand: Eaton Cutler-Hammer
Model #: FH57
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With A200/B100 Starter Size 2

$86.38

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Overload Relays Starter Type: IEC NEMA Size: 00-1


Item #: 55942130
Brand: Schneider Electric
Model #: LR9D32
Exact Tooling IR#: 04

Product Specifications

Overload Relays; Starter Type: IEC ; NEMA Size: 00-1 ; For Use With: LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38 ; Voltage: 690 V
Starter Type IEC
NEMA Size 00-1
For Use With LC1D09; LC1D12; LC1D18; LC1D25; LC1D32; LC1D38
Voltage 690 V

$157.71

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, 12 Amp, 120 Coil VAC, Nonreversible Enclosed IEC Motor Starter - 1 Phase Hp: 0.5 at 120 VAC, 2 at 240 VAC, 3 Phase Hp: 10 at 575 VAC, 3 at 208 VAC, 3 at 230 VAC, 7.5 at 460 VAC


Item #: 69665164
Brand: Schneider Electric
Model #: LE1D123A62OG70
Exact Tooling IR#: 04

Features and Benefits

Enclosed full voltage starters connect the incoming power directly to the motor and are used in applications where the motor runs in only one direction and speed.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Starter Type Enclosed Full Voltage Starter
Amperage 12
Coil Voltage 120 VAC
Action NonReversible
Auxiliary Contact Configuration NC/NO
Horsepower at 3 Phase 10 @ 575 VAC; 3 @ 208 VAC; 3 @ 230 VAC; 7.5 @ 460 VAC
Horsepower at 1 Phase 0.5 @ 120 VAC; 2 @ 240 VAC
Enclosure Type Enclosed
Number of Poles 3
Standards Met CSA; IEC; NEMA 1; UL

$232.24

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 2 Poles, 0.4 to 16 Amp, NEMA, Open Toggle Manual Motor Starter - 43.2mm Wide x 40.1mm Deep x 96.8mm High, 1 hp at 120/240 V, 1 hp at 277 V & 1/4 hp at 32 V, CSA Certified & UL Listed


Item #: 01259670
Brand: Eaton Cutler-Hammer
Model #: MST02
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Amperage refers to the maximum electrical current the product is intended to accommodate.
Toggle switches are designed for safety and speed of an operation. They closes or open contacts with a lever.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Product Specifications
Starter Type NEMA
Amperage 0.40-16
Operator Type Toggle
Enclosure Type Open
Horsepower (HP) 1 @ 120/240 V; 1 @ 277 V; 1/4 @ 32 V
Number of Poles 2
Overall Height (mm) 96.80
Overall Height (Decimal Inch) 3.8100
Overall Width (mm) 43.20
Overall Width (Decimal Inch) 1.7000
Overall Depth (mm) 40.10
Overall Depth (Decimal Inch) 1.5800
Standards Met CSA Certified; UL Listed

$291.36

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 48 to 65 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D50A and LC1D65A


Item #: 56829088
Brand: Schneider Electric
Model #: LRD3656
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D50A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 65
Sensing Method Thermal
Minimum Overload (A) 48
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$160.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 48 to 65 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D50A and LC1D65A


Item #: 59032672
Brand: Schneider Electric
Model #: LRD365
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D50A; LC1D65A
Voltage 690 VAC
Maximum Overload (A) 65
Sensing Method Thermal
Minimum Overload (A) 48
Trip Class 10A
Overall Height (mm) 70
Overall Width (mm) 123
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$148.77

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 3, 600 VAC, Thermal NEMA Overload Relay


Item #: 54421474
Brand: Square D
Model #: 9065SDO12
Exact Tooling IR#: 04

Product Specifications

NEMA Size 3, 600 VAC, Thermal NEMA Overload Relay -
Starter Type NEMA
NEMA Size 3
Voltage 600 VAC
Sensing Method Thermal
Standards Met CE; CSA; UL Listed

$317.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 9 Amp, 120 Coil VAC, 50/60 Hz, IEC Motor Starter - 3 Phase Hp: 5


Item #: 69681112
Brand: Schneider Electric
Model #: ATS01N209RT
Exact Tooling IR#: 04

Features and Benefits

Soft starters, also known as RVS (Reduced Voltage Starting), is generally used with large horsepower motors to reduce the inrush current and limit the torque output that can cause mechanical stress on the load.
Product Specifications
Starter Type Soft Starter
Amperage 9
Coil Voltage 120 VAC
Horsepower at 3 Phase 5
Frequency Rating (Hz) 50/60
Overall Height (mm) 124
Overall Height (Decimal Inch) 4.8800
Overall Width (mm) 45
Overall Width (Decimal Inch) 1.7700
Overall Depth (mm) 131
Overall Depth (Decimal Inch) 5.1600
Standards Met B44.1-96/ASME A17.5; CCC; CE; CSA; C-Tick; EN/IEC 60947-4-2; GOST; IEC 61000-4-5 Level 3; RoHS Compliant; UL

$179.17

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 380 to 630 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F400, LC1F630 and LC1F800


Item #: 56805617
Brand: Schneider Electric
Model #: LR9F7381
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F400; LC1F630; LC1F800
Voltage 1000 VAC
Maximum Overload (A) 630
Sensing Method Thermal
Minimum Overload (A) 380
Trip Class 20
Overall Height (mm) 127.60
Overall Width (mm) 136.80
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$1,354.43

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - NEMA Size 7, 270 to 810 Amp, 600 VAC, Thermal NEMA Overload Relay - Trip Class 10 and 20, For Use with Square D Class 8536 Starters


Item #: 56825136
Brand: Square D
Model #: 9065ST720
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 7
For Use With Square D Class 8536 Starters
Voltage 600 VAC
Maximum Overload (A) 810
Sensing Method Thermal
Minimum Overload (A) 270
Trip Class 10; 20

$337.11

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Control Unit - For Use with LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN, LUFV2, LUFW10


Item #: 56829484
Brand: Schneider Electric
Model #: LUCB18ES
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Control Unit
For Use With LUFC00; LUFDA01; LUFDA10; LUFDH11; LUFN; LUFV2; LUFW10

$226.97

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - Starter Heater - For Use with MS Starters


Item #: 01259852
Brand: Eaton Cutler-Hammer
Model #: MSH2-5A
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Heater
For Use With MS Starters

$67.89

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 3 Pole, 110 VAC at 50 Hz, 120 VAC at 60 Hz and 600 Volt, 18 Continuous Amp, 1 hp, Open NEMA Combination Starter - ABS Type Approved, cUL Listed, NEMA ICS 2-1993, UL Listed


Item #: 02353142
Brand: Eaton Cutler-Hammer
Model #: CN15BN3AB
Exact Tooling IR#: 04

Features and Benefits

National Electrical Manufacturers' Association (NEMA) starters are electrically controlled switches used to rapidly open (break) and close (make) a circuit. They are larger than the International Electrotechnical Commission (IEC) starters and are considred more rugged and durable.
Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Single or three-phase refers to either a single coil or three individual coils that connect to and run voltage through the connector. Single-phase lines are used for light-to-medium operations and three-phase lines are used for medium-to-heavy operations.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Product Specifications
Continuous Amperage 18
Starter Type NEMA
Enclosure Type Open
Compatible Motor Phase Single Phase, Three Phase
Action NonReversible
Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz; 600 V
Number of Poles 3
Horsepower (HP) 1
Overall Height (mm) 98.60
Overall Height (Decimal Inch) 3.8800
Overall Width (Decimal Inch) 1-3/4
Overall Width (mm) 44-1/2
Overall Depth (mm) 88.60
Overall Depth (Decimal Inch) 3.4900
Standards Met ABS Type Approved; cUL Listed; NEMA ICS 2-1993; UL Listed

$731.17

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 37 to 50 Amp, 690 VAC, Thermal IEC Overload Relay - Trip Class 10A, For Use with LC1D80 and LC1D95


Item #: 69975571
Brand: Schneider Electric
Model #: LRD3357
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1D80; LC1D95
Voltage 690 VAC
Maximum Overload (A) 50
Sensing Method Thermal
Minimum Overload (A) 37
Trip Class 10A
Overall Height (mm) 123
Overall Width (mm) 121
Standards Met ATEX 94/9/CE; CSA C22.2 No. 14; EN/IEC 60947-4-1; EN/IEC 60947-5-1; RoHS Compliant; UL 508

$146.22

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Starter Communication Module - For Use with LUCA, LUCB, LUCC, LUCD, LUCL, LUCM


Item #: 54524210
Brand: Schneider Electric
Model #: LULC08
Exact Tooling IR#: 04

Product Specifications
Starter Accessory Type Communication Module
For Use With LUCA; LUCB; LUCC; LUCD; LUCL; LUCM

$308.34

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 30 to 50 Amp, 1,000 VAC, Thermal IEC Overload Relay - Trip Class 20, For Use with LC1F115 and LC1F185


Item #: 56805609
Brand: Schneider Electric
Model #: LR9F5557
Exact Tooling IR#: 04

Product Specifications
Starter Type IEC
For Use With LC1F115; LC1F185
Voltage 1000 VAC
Maximum Overload (A) 50
Sensing Method Thermal
Minimum Overload (A) 30
Trip Class 20
Overall Height (mm) 96
Overall Width (mm) 123-1/2
Standards Met EN/IEC 60947-4-1; IEC 60255-17; IEC 60255-8; VDE 0660

$445.99

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 600 Volt, Thermal NEMA Overload Relay


Item #: 56812654
Brand: Square D
Model #: 9065SEO4S1
Exact Tooling IR#: 04

Product Specifications

600 Volt, Thermal NEMA Overload Relay -
Starter Type NEMA
Voltage 600 V
Sensing Method Thermal

$95.78

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Pole, NEMA Size 1, 23 to 32 Amp, 690 VAC, Thermal NEMA Overload Relay - Trip Class 20, For Use with LC1D25, LC1D32 and LC1D38


Item #: 69527422
Brand: Schneider Electric
Model #: LRD32L
Exact Tooling IR#: 04

Product Specifications
Starter Type NEMA
NEMA Size 1
For Use With LC1D25; LC1D32; LC1D38
Voltage 690 VAC
Maximum Overload (A) 32
Sensing Method Thermal
Minimum Overload (A) 23
Trip Class 20
Number of Poles 3
Overall Depth (mm) 76.10
Overall Depth (Inch) 3
Overall Width (Decimal Inch) 1.7700
Overall Width (mm) 45
Standards Met ABS; ATEX D 94/9/CE; ATEX INERIS; CSA; CSA C22.2 No. 14; EAC; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL; UL 508

$94.84

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It