Square D - 30 Amp, 277 VAC, 1 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 12-4 (Aluminum), 14-6 (Copper) AWG, 4.05 Inch Deep x 5.66 Inch High x 0.98 Inch Wide
Item #: 69531796
Brand: Square D
Model #: EDB14030EPD
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
30
Number of Poles
1
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
277 VAC
Wire Size (AWG)
12-4 (Aluminum); 14-6 (Copper)
Overall Depth (Decimal Inch)
4.0500
Overall Height (Decimal Inch)
5.6600
Overall Width (Decimal Inch)
0.9800
For Use With
NF Panelboard
Standards Met
CSA C22.2; UL 1053; UL 489
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 25 kA at 347 VAC, 65 kA at 277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41397472
Brand: Square D
Model #: BJA160301
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 347 VAC; 65 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41398751
Brand: Square D
Model #: BDA160301
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 18 kA at 347 VAC, 35 kA at 277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41394453
Brand: Square D
Model #: BGA160301
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
65 kA @ 240 V; 18 kA @ 347 VAC; 35 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
347 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 25 kA at 347 VAC, 65 kA at 277 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41397043
Brand: Square D
Model #: BJL16030
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 347 VAC; 65 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41399320
Brand: Square D
Model #: BDL16030
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 18 kA at 347 VAC, 35 kA at 277 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41384256
Brand: Square D
Model #: BGL16030
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
65 kA @ 240 VAC; 18 kA @ 347 VAC; 35 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 V, 2 Pole, Bolt On Miniature Circuit Breaker - 35 kA Breaking Capacity, 12, 14 AWG
Item #: 69660777
Brand: Square D
Model #: EGB24030
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
2
Breaking Capacity
35 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 V, 3 Pole, Bolt On Miniature Circuit Breaker - 35 kA Breaking Capacity, 12, 14 AWG
Item #: 69668655
Brand: Square D
Model #: EGB34030
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
35 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 V, 3 Pole, Bolt On Miniature Circuit Breaker - 65 kA Breaking Capacity, 12, 14 AWG
Item #: 69660645
Brand: Square D
Model #: EJB34030
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
65 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41399726
Brand: Square D
Model #: BDA24030Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 V, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41394511
Brand: Square D
Model #: BGA24030Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
2
Breaking Capacity
65 kA @ 240 V; 35 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41399502
Brand: Square D
Model #: BDA34030Y
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41383852
Brand: Square D
Model #: BGA34030Y
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 Volt, 2 Pole, Bolt On Miniature Circuit Breaker - 18 kA Breaking Capacity, 12, 14 AWG
Item #: 69660868
Brand: Square D
Model #: EDB24030
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
2
Breaking Capacity
18 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 480Y/277 Volt, 3 Pole, Bolt On Miniature Circuit Breaker - 18 kA Breaking Capacity, 12, 14 AWG
Item #: 42793737
Brand: Square D
Model #: EDB34030
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
18 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600 V, 3 Pole Fused Safety Switch - NEMA 1, 7.5 hp at 480 VAC (Single Phase), 20 hp at 600 VAC (Triple Phase)
Item #: 56755291
Brand: Square D
Model #: H361EI
Exact Tooling IR#: 04
Product Specifications
NEMA Enclosure Rating
1
Fused
Fused
Number of Poles
3
Amperage
30
Voltage
600 V
Horsepower at 1 Phase
7.5 @ 480 VAC
Horsepower at 3 Phase
20 @ 600 VAC
Contact Configuration
NO/NC
Standards Met
UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600 V, 3 Pole Fused Safety Switch - NEMA 3R, 3 Phase, 7.5 hp at 480 VAC (Single Phase), 20 hp at 600 VAC (Triple Phase), 3PST Contact Form
Item #: 56754310
Brand: Square D
Model #: H361RBVW
Exact Tooling IR#: 04
Product Specifications
NEMA Enclosure Rating
3R
Fused
Fused
Number of Poles
3
Amperage
30
Voltage
600 V
Horsepower at 1 Phase
7.5 @ 480 VAC
Horsepower at 3 Phase
20 @ 600 VAC
Number of Phases
3
Contact Form
3PST
Number of Wires
3
Overall Height (mm)
378
Overall Height (Decimal Inch)
14.8800
Overall Width (mm)
168
Overall Width (Decimal Inch)
6.6300
Overall Depth (Decimal Inch)
4.8800
Overall Depth (mm)
124
Standards Met
NEMA Standard KS1; UL Listed File E2875 & 154828
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600 V, 3 Pole Nonfused Safety Switch - NEMA 1, 10 hp at 600 VAC, 15 at 600 VDC (Single Phase), 30 hp at 600 VAC, 15 hp at 600 VDC (Triple Phase)
Item #: 56754823
Brand: Square D
Model #: HU361VW
Exact Tooling IR#: 04
Product Specifications
NEMA Enclosure Rating
1
Fused
NonFused
Number of Poles
3
Amperage
30
Voltage
600 V
Horsepower at 1 Phase
10 HP @ 600 VAC, 15 @ 600 VDC
Horsepower at 3 Phase
30 @ 600 VAC, 15 @ 600 VDC
Standards Met
UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600 V, 3 Pole Nonfused Safety Switch - NEMA 12 & 3R, 10 hp at 600 VAC (Single Phase), 30 hp at 600 VAC (Triple Phase)
Item #: 56753213
Brand: Square D
Model #: HU361AWKEI4MVW
Exact Tooling IR#: 04
Product Specifications
NEMA Enclosure Rating
12; 3R
Fused
NonFused
Number of Poles
3
Amperage
30
Voltage
600 V
Horsepower at 1 Phase
10 HP @ 600 VAC
Horsepower at 3 Phase
30 @ 600 VAC
Contact Configuration
2NO/2NC
Standards Met
UL Listed