We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Products - (25001 Products)


Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740442
Brand: Square D
Model #: HDL36150U44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$4,140.61

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740467
Brand: Square D
Model #: HDL36150U33X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$4,000.41

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740103
Brand: Square D
Model #: HLL36150U31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 480 VAC; 125 kA @ 240 VAC; 50 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$8,166.10

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740160
Brand: Square D
Model #: HJL36150U43X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$6,448.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740293
Brand: Square D
Model #: HGL36150U43X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$5,839.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56741481
Brand: Square D
Model #: HJL36150CU33X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0

$7,576.24

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56740459
Brand: Square D
Model #: HDL36150U43X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$3,735.22

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56741424
Brand: Square D
Model #: HGL36150CU31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0

$4,642.69

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG, 88.6mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56741564
Brand: Square D
Model #: HRL36150U31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 600 VAC; 200 kA @ 240 VAC; 200 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4900
Overall Depth (mm) 88.60
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$12,387.05

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56748452
Brand: Square D
Model #: HJL36150T
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$4,824.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56746332
Brand: Square D
Model #: HGM36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,356.01

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747967
Brand: Square D
Model #: HGF36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Busbar
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,356.01

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56739865
Brand: Square D
Model #: HDF36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Busbar
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$2,152.15

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56743867
Brand: Square D
Model #: JGF36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Busbar
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$3,433.78

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56744121
Brand: Square D
Model #: JDP36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$2,015.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56744600
Brand: Square D
Model #: JDF36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Busbar
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; RoHS Compliant; UL Listed
Reset Actuator Type Toggle Switch

$2,155.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide


Item #: 56743214
Brand: Square D
Model #: JJP36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 191
Overall Height (Decimal Inch) 7.5200
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$4,723.29

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747686
Brand: Square D
Model #: HDS36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Rear Connected
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$3,523.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747694
Brand: Square D
Model #: HDP36150
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$2,474.98

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 150 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56740426
Brand: Square D
Model #: HDP36150U44X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 150
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$4,761.71

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It